@licson 你的 PERC 是用 RAID mode 還是 HBA mode ?
正常狀態 沒 bbu 的話 writeback 會變 writethrough
# megacli -LDInfo -Lall -aALL
Adapter 0 -- Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name :PVE-R720xd
RAID Level : Primary-6, Secondary-0, RAID Level Qualifier-3
Size : 36.381 TB
Sector Size : 512
Parity Size : 7.276 TB
State : Optimal
Strip Size : 64 KB
Number Of Drives : 12
Span Depth : 1
Default Cache Policy: WriteBack, ReadAdaptive, Cached, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAdaptive, Cached, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy : Enabled
Encryption Type : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: No
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
Is VD Cached: Yes
Cache Cade Type : Read Only
Exit Code: 0x00
# megacli -AdpBbuCmd -GetBbuStatus -aALL
BBU status for Adapter: 0
BatteryType: BBU
Voltage: 3924 mV
Current: 0 mA
Temperature: 37 C
Battery State: Optimal
BBU Firmware Status:
Charging Status : None
Voltage : OK
Temperature : OK
Learn Cycle Requested : No
Learn Cycle Active : No
Learn Cycle Status : OK
Learn Cycle Timeout : No
I2c Errors Detected : No
Battery Pack Missing : No
Battery Replacement required : No
Remaining Capacity Low : No
Periodic Learn Required : No
Transparent Learn : No
No space to cache offload : No
Pack is about to fail & should be replaced : No
Cache Offload premium feature required : No
Module microcode update required : No
BBU GasGauge Status: 0x0038
Relative State of Charge: 98 %
Charger Status: Complete
Remaining Capacity: 405 mAh
Full Charge Capacity: 414 mAh
isSOHGood: Yes
Exit Code: 0x00
一個我戳兩下就有的結果我幹嘛還要裝一個超難裝的perccli啦((((
# megacli -AdpAllInfo -aALL
Adapter #0
==============================================================================
Versions
================
Product Name : PERC H710P Mini
Serial No : 3AU0472
FW Package Build: 21.3.5-0002
Mfg. Data
================
Mfg. Date : 10/31/13
Rework Date : 10/31/13
Revision No : A03
Battery FRU : N/A
Image Versions in Flash:
================
BIOS Version : 5.42.00.1_4.12.05.00_0x05290003
Ctrl-R Version : 4.04-0003
Preboot CLI Version: 05.00-03:#%00008
FW Version : 3.131.05-8148
NVDATA Version : 2.1108.03-0097
Boot Block Version : 2.03.00.00-0004
BOOT Version : 06.253.57.219
你去生一個 centos based 的 pve 來
還有套件可以讓 backplane 做到 U.2 直通
我覺得一臉是二手貨的鍋,總感覺前人搞了一個超會lag的qd讓我也很lag
H710 -> H730 以後我覺得 SSD RAID 變快了
我覺得問題在pve不認得perc然後host很快guest很慢
如果你能接受我嘗試性實驗而離線半天以上的話,我週六晚上執行
有人知道 Android Ethernet 怎麼固定 IP 嗎
我用 ifup 加 ip 跟我說沒有 /etc/net works
他也只是不小心把 development 環境和 production 環境搶了 IP 讓東西直接裸奔上去而已
都已經有 docker for solaris 了
結果丟了好久昨天才開起來的rack
剛剛看才發現corosync一直沒開上
而且還是被其他開很久的機器的corosync霸凌 🙈
不是啊 都戳cli還不如自己用lxc/kvm
還不用被pve綁東綁西不是嗎 🤔
按照pve邏輯應該先判斷本機上有沒有
沒有call cluster api找他在哪台
然後再ssh過去幫忙戳pct這樣 🌚
還是不懂為毛我有些LXC在自動開機會失敗 然後之後手動開就正常 🤔
systemd刚出的时候,好多服务挂掉就是因为竞争条件))
不知為毛
反正都是timeout
原因暫且不明(?
lxc預設沒任何log超麻煩QQ
靠競爭來確保時序正確不是 broken by design 嘛
天知道會不會因為哪天因為宇宙的神祕力量順序就不對了
fat finger 笑死 wwwwwwwwwwwwww
歐 然後我是prometheus派的 所以這對我沒差(?
只是公司有政策不能開 port 所以只好都自幹 influxdb client
其實 prometheus 或是 graphite 在跨節點都比 influx 好
我現在用了 Influx 發現不能開 shard 很痛苦
用influx只是因為不能在probe node開port而已
🤔
不開port還是很多辦法啊
除非雙向都戳不到
不過prometheus走HTTP
所以方法多的是🌚
🤔
反正我不管influxdb/graphite全都用prometheus收🌚
然而我覺得就算要push還是能用啊
這幾家實際上都互相支援各自proto(((
目前各種db最簡單搞得就 AA AS 但是 AAS 超麻煩
然後為了完成一個 cluster 要找第三臺來滿足條件
買兩臺 Oracle SPARC T4-4 就是做 DB……