# megacli -LDInfo -Lall -aALL
Adapter 0 -- Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name :PVE-R720xd
RAID Level : Primary-6, Secondary-0, RAID Level Qualifier-3
Size : 36.381 TB
Sector Size : 512
Parity Size : 7.276 TB
State : Optimal
Strip Size : 64 KB
Number Of Drives : 12
Span Depth : 1
Default Cache Policy: WriteBack, ReadAdaptive, Cached, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAdaptive, Cached, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy : Enabled
Encryption Type : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: No
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
Is VD Cached: Yes
Cache Cade Type : Read Only
Exit Code: 0x00